Green Ship Test & Certification Center
Facility
Testing & Certification Canter
Engine Research Building
Low Speed Engine Cell
- Portable PM Sampler
- Model name : Micro-PSS
- Nation : Italy
- Company : CONTROL SISTEM
Possession Information
Agency | Korean Register |
---|---|
Application | Test, Evaluation, and R&D |
Location | Green Ship TCC, Low Speed Engine Cell |
Purpose
Usage I | Particulate matter sampling for both measurement of PM mass and analysis on PM composition |
---|
Summary
- 1. Pumps maximum flow : 2m3/h
- 2. Flow meters accuracy : ±0.2 % of reading
- 3. Transformation time (ISO 16183) : < 0.15 s
- 4. Standard regression correlation coefficient [R] : > 0.98
- 5. Dilution factor : Constant or variable
- 6. Filter size : 47mm
- 7. Dilution air filter : HEPA